V3 shuts off alternator

For all issues involving the Smart Alternator Regulators, V1, V2 and V3

V3 shuts off alternator

Postby DonRus on Thu Jul 12, 2012 5:07 pm

When the batteries in my trawler become fully charged while underway, the V3 shuts off the alternator. This occurs erratically. If I shut down and restart the engine the alternator comes back on line. Turning on a load, like the overhead lights, does not solve the problem. Any suggestions as to how I can solve the problem?
DonRus
 
Posts: 2
Joined: Wed Jul 11, 2012 11:10 am

Re: V3 shuts off alternator

Postby Coulomb on Thu Jul 12, 2012 10:50 pm

This sounds like the transition to float. Have you read this information? http://www.amplepower.com/primer/tach/index.html

What does the volt meter display when this happens?
Coulomb
Site Admin
 
Posts: 1174
Joined: Sat Jun 06, 2009 5:11 pm

Re: V3 shuts off alternator

Postby DonRus on Fri Jul 13, 2012 10:30 am

The reference gives a good explanation and I will check to see if my Perkins diesel has a plug for a RPM sensor. The voltage is over 14 volts when the alternator is shut off.
Thanks for the help.
DonRus
 
Posts: 2
Joined: Wed Jul 11, 2012 11:10 am

Re: V3 shuts off alternator

Postby Coulomb on Fri Jul 13, 2012 11:29 am

The 14V indicates that the alternator is maintaining battery voltage, but the alternator is producing so little current that the tach signal is too weak.
Coulomb
Site Admin
 
Posts: 1174
Joined: Sat Jun 06, 2009 5:11 pm