troubleshooting green light 3 on / 3 off

For issues involving the NS2 regulator.

troubleshooting green light 3 on / 3 off

Postby Weber on Mon Jul 15, 2013 11:47 am

On Fri, July 12, 2013 9:13 pm, Weber, Darrell D. wrote:
> I just purchased this boat. The previous installed regulator was not
> working. The previous owner actually flipped a switch on and off to
> charge or not charge the batteries and he monitored the charge with
> his Xantrex. He had purchased the NS2 regulator but never installed
> it. I installed the NS2 a few weeks ago. I thought charged for a few
> minutes the first day but the batteries were near fully charged so I
> was not concerned. I went out cruising last week and noted that the
> house batteries that are charged by the 2nd alternator were not
> charging so I had to run the generator if necessary to charge the
> house. When I returned to the marina I looked for the error codes. I
> had an error code indicating no batt / volts. I corrected that
> situation. I also had a green 3 sec on / 3 sec off light blinker. I
> have not been able to get the alternator to charge or the green 3 on /
> 3 off blinker to change. I did the alternator output check described
> in the troubleshoot guide. It charges and registers on my DC amp
> meter that monitors the alternator output. I read many of the forum
> post but have not located one that addresses this issue.
>
> Any assistance is appreciated.
>
> Thanks
>
> Darrell
Weber
 
Posts: 2
Joined: Mon Jul 15, 2013 11:38 am

Re: troubleshooting green light 3 on / 3 off

Postby Coulomb on Mon Jul 15, 2013 6:03 pm

The green LED is telling you that there is no "ON" voltage, TB1-5.
Coulomb
Site Admin
 
Posts: 1174
Joined: Sat Jun 06, 2009 5:11 pm

Re: troubleshooting green light 3 on / 3 off

Postby Weber on Wed Jul 17, 2013 4:10 pm

Coulomb - Sorry but I am more of a mechanical type guy. Are you saying the regulator it is working properly but since the batteries are charged the alternator field is not excited, meaning the regulator is doing it's job and not overcharging the batteries? If it's not working correctly what and how should I test to find the issue? I can disconnect from shore power and drain the batteries some if necessary
Weber
 
Posts: 2
Joined: Mon Jul 15, 2013 11:38 am

Re: troubleshooting green light 3 on / 3 off

Postby Coulomb on Wed Jul 17, 2013 5:33 pm

You need to tell the regulator to start regulating by applying battery voltage to TB1-5. Typically this is done through the ignition switch or a oil pressure switch.