no field v

For Next Step Regulators including Lifeline units. Use the NS2 forum for NS2 issues.

no field v

Postby hugh on Thu Nov 18, 2010 5:02 am

Hi I need help solving this problum.
H battery 12.8 - 121.8- 12.8 ok
par 12.8 - 12.8- 12.8 ok no charge so as expecded
on/off 0- 12.5 - 12.5 ok
gr 0 - 0 - 0- ok
b+ 12.8 - 12.8- 12.8 ok
field 0- 0- 0
alt 0 0- 0 ok
lock 0- 0- 0 ok
bat.v 12.8 - 12.8- 12.8 ok
t- 0 - 0 -0 ok not conected
t+ 0 - 4.75- 4.78 ok not conected
asb 0- 0- 0 ok
lamp 0 -21.58- 12.44 (after red light goes out) ok

Alternator test by supling power to field.

PROBLUM no V' at field.

Hope you can help Hugh
hugh
 
Posts: 1
Joined: Thu Nov 18, 2010 12:06 am

Re: no field v

Postby Coulomb on Thu Nov 18, 2010 11:08 am

It appears to be a failed regulator.


Send products for repair to:
Ample Power Company, LLC.
6315 Seaview Avenue, NW
Seattle, WA 98107
Coulomb
Site Admin
 
Posts: 1174
Joined: Sat Jun 06, 2009 5:11 pm


Return to Next Step Regulators

Who is online

Users browsing this forum: No registered users and 1 guest